Compliancy Testing
Compliancy Testing
Your Questions. Our Expertise.
Understanding your ongoing fire safety testing responsibilities and keeping your building protected.
Practical guidance on fire alarm testing, emergency lighting, automatic opening vents and routine fire safety management for businesses, landlords and property managers.
Request Your Free Quote Explore Our Testing ServicesUnderstanding Your Testing Responsibilities
Different fire safety systems require different testing and maintenance arrangements.
Fire Alarm Testing
Routine functional testing of your fire alarm system to help identify operational faults and maintain effective fire safety arrangements.
Emergency Lighting Testing
Routine functional checks to confirm emergency lighting operates when its normal electrical supply fails.
Smoke Ventilation & AOVs
Routine operational checks in accordance with the system design, manufacturer guidance and applicable maintenance requirements.
Typical testing arrangements are shown above. Individual requirements depend on the premises, system design and applicable guidance.
What Would You Like to Know?
Choose a category to explore your fire safety testing responsibilities.
Legal Responsibilities & Maintenance
What is fire safety compliancy testing?
Compliancy testing refers to the routine operational checks undertaken to help ensure fire safety systems remain functional between scheduled professional maintenance visits.
These checks may include weekly fire alarm testing, monthly emergency lighting testing and routine checks of smoke ventilation systems.
Regular testing helps identify faults, maintain appropriate records and support the Responsible Person in managing ongoing fire safety duties.
Is routine fire safety testing a legal requirement?
Under Article 17 of the Regulatory Reform (Fire Safety) Order 2005, relevant fire safety equipment and facilities must be subject to a suitable system of maintenance and maintained in efficient working order and good repair.
Routine testing forms an important part of an appropriate maintenance and fire safety management regime.
Recognised British Standards provide guidance on suitable testing and maintenance frequencies.
Although British Standards are not themselves legislation, they provide recognised benchmarks for demonstrating appropriate fire safety management.
Who is responsible for routine fire safety testing?
The Responsible Person must ensure that appropriate testing and maintenance arrangements are in place.
Depending on the premises, this may involve employers, landlords, freeholders, managing agents or other parties exercising relevant control.
Testing can be delegated to appropriately instructed staff or an external service provider, but the Responsible Person retains their applicable statutory duties.
What is the difference between testing and servicing?
Routine testing and professional servicing are separate but complementary activities.
Routine testing is intended to confirm basic operational functionality and identify obvious faults between scheduled maintenance visits.
Professional servicing involves more detailed inspection, maintenance and technical assessment by a competent person.
| System | Routine Testing | Professional Maintenance |
|---|---|---|
| Fire Alarm | Typically weekly | Typically at intervals not exceeding six months |
| Emergency Lighting | Typically monthly functional testing | Annual full-rated-duration testing and appropriate maintenance |
| Smoke Ventilation / AOV | System-specific scheduled checks | Competent specialist maintenance at appropriate intervals |
The exact requirements depend on the system type, applicable standards, manufacturer instructions and the building's fire safety arrangements.
Routine testing does not replace professional servicing, and professional servicing does not remove the need for routine testing.
Can our own staff carry out routine testing?
Yes. Many routine fire safety checks can be undertaken by appropriately instructed and authorised members of staff.
Staff must understand the relevant testing procedure, system operation, reporting arrangements and what action to take if a fault is identified.
Outsourcing routine testing can provide greater consistency, particularly where staff availability, holidays, multiple locations or access arrangements present challenges.
What happens if routine testing is not carried out?
Faults may remain undetected, potentially compromising the effectiveness of fire safety systems.
Inadequate testing and maintenance arrangements may also contribute to enforcement action, prosecution or insurance complications, depending on the circumstances.
Maintaining a suitable testing regime and addressing identified defects promptly are important elements of effective fire safety management.
Fire Alarms, Emergency Lighting & AOVs
How often should a commercial fire alarm be tested?
Fire alarm systems in non-domestic premises should normally be tested weekly in accordance with the recommendations of BS 5839-1.
Testing should normally be undertaken at approximately the same time each week, with suitable arrangements for occupants and any alarm receiving centre.
A different manual call point should normally be used each week where multiple call points are provided.
The results should be recorded and any identified faults reported for appropriate attention.
What does a weekly fire alarm test involve?
A routine weekly test normally involves operating a manual call point and checking that the fire alarm system responds appropriately.
The system should be checked for obvious fault indications and restored to its normal operating condition following the test.
The test should be documented, including the call point tested and any defects identified.
Testing arrangements must account for monitored systems, connected equipment and the building's cause-and-effect arrangements.
Does weekly fire alarm testing replace six-monthly servicing?
No. Weekly fire alarm testing is a routine user check.
Professional inspection and servicing under BS 5839-1 involves more detailed technical checks, with intervals normally not exceeding six months.
Both activities form part of a suitable fire alarm maintenance and management programme.
How often should emergency lighting be tested?
Emergency escape lighting should normally undergo a monthly functional test and an annual full-rated-duration test.
Routine visual monitoring of relevant system indicators may also be required, depending on the system design.
Testing arrangements should follow applicable emergency lighting standards, including BS EN 50172, and manufacturer guidance.
Automatic testing systems may provide an alternative method of undertaking and recording certain tests.
What is a monthly emergency lighting test?
A monthly functional test checks that emergency luminaires operate when their normal electrical supply is interrupted.
This is sometimes referred to as a flick test.
The test should be long enough to confirm operation without unnecessarily discharging the batteries.
Any failed luminaires or other defects should be recorded and reported for appropriate remedial action.
What is an annual emergency lighting duration test?
An annual duration test checks whether emergency lighting continues to operate for its specified rated emergency duration.
Many commercial systems are designed for three hours of emergency operation, although the required duration depends on the building and system design.
Testing must be appropriately planned to account for battery recharge times and the continued safety of building occupants.
A monthly functional test does not demonstrate that a luminaire can achieve its full rated duration.
What is an automatic opening vent or AOV?
An automatic opening vent is a component of a smoke ventilation system designed to open under specified operating conditions.
Depending on the system design, smoke ventilation can help manage smoke within communal corridors, stairwells and other protected areas.
These systems are particularly important in many multi-occupied residential buildings.
How often should AOVs and smoke ventilation systems be tested?
Smoke ventilation systems require appropriate routine checks and specialist maintenance.
Testing frequencies depend on the system design, fire strategy, manufacturer instructions and applicable standards and guidance.
Monthly operational checks may form part of a suitable testing programme, but there is no single universal interval appropriate to every smoke ventilation system.
Additional statutory monthly checking duties apply to relevant smoke control equipment in high-rise residential buildings in England under the Fire Safety (England) Regulations 2022.
Does an AOV operational test replace specialist servicing?
No. Routine operational testing helps identify obvious functional problems but does not replace specialist inspection and maintenance.
Smoke ventilation systems may incorporate detectors, control panels, actuators, power supplies, dampers and other interconnected components.
Specialist maintenance is necessary to assess the system against its intended design and applicable technical requirements.
Record Keeping, Outsourcing & Our Services
Do I need to keep records of fire safety testing?
Maintaining suitable testing and maintenance records is an important part of demonstrating effective fire safety management.
Records should normally include:
- The date of the test.
- The system or equipment tested.
- The person undertaking the test.
- The results of the test.
- Any faults or defects identified.
- Details of reporting and follow-up action.
Records should be readily available for management review and inspection by relevant enforcing authorities where required.
What should happen when a fault is identified?
Identified faults should be recorded and reported promptly to the Responsible Person or designated property management contact.
Appropriate remedial action should be arranged through a competent service provider.
Where a fault compromises fire safety arrangements, the Responsible Person should assess the risk and implement suitable interim measures where necessary.
Can I outsource my weekly and monthly fire safety testing?
Yes. Outsourcing routine testing allows businesses and property managers to establish a consistent, scheduled testing programme.
Virtus Fire provides routine compliancy testing services across London and the Home Counties.
Our services are particularly suited to organisations that manage multiple properties, have limited on-site staffing or require reliable testing arrangements throughout the year.
What are the benefits of outsourcing routine testing?
- Consistent scheduled attendance.
- Reduced reliance on internal staff.
- Documented testing records.
- Prompt reporting of identified faults.
- Improved oversight across multiple properties.
- Reduced administrative workload.
- Predictable ongoing service costs.
Outsourcing supports the Responsible Person in managing their obligations but does not transfer their statutory responsibilities.
Can Virtus Fire manage multiple properties?
Yes. We work with property managers, managing agents, landlords and businesses to deliver coordinated testing programmes across individual buildings and extensive property portfolios.
Our scheduled services help clients maintain consistent testing arrangements without having to coordinate separate internal resources at every location.
How much does compliancy testing cost?
Costs depend on the location, number of properties, systems installed, testing requirements and frequency of attendance.
We provide tailored quotations for individual premises and multi-site property portfolios.
Routine testing can also be incorporated into a bespoke monthly Virtus Fire Compliance Care Plan.
Request Your Free, No-Obligation QuoteFurther Fire Safety Guidance
For additional information about fire safety responsibilities and maintenance requirements, consult the following official guidance.
GOV.UK – Workplace Fire Safety →
Regulatory Reform (Fire Safety) Order 2005 – Article 17 →
Fire Safety (England) Regulations 2022 →
This page provides general guidance, principally relating to England. Individual testing and maintenance requirements depend on the premises, system design, applicable standards, manufacturer instructions and fire risk assessment.
Reliable Testing. Clear Reporting. Peace of Mind.
Let us take care of your routine fire safety testing programme, so you can concentrate on managing your business or property portfolio.
Scheduled Attendance
Regular testing visits arranged around your building's requirements and agreed service schedule.
Documented Results
Clear records of completed tests to support your ongoing fire safety management arrangements.
Proactive Fault Reporting
Identified defects reported to the appropriate contact, helping you arrange timely remedial action.
Total Compliance. One Cost.
Managing your fire safety responsibilities shouldn't mean juggling multiple contractors, testing schedules and unexpected invoices.
Our bespoke Compliance Care Plans bring your agreed fire safety services together into one coordinated package.
Routine Testing
Weekly fire alarm testing, monthly emergency lighting checks and agreed smoke ventilation testing arrangements.
Wider Fire Safety
Fire risk assessments, fire door inspections, extinguisher servicing and other agreed fire safety services.
Predictable Costs
A tailored service package with manageable monthly payments, designed around your premises and agreed requirements.
Let Us Take Care of Your Compliancy Testing
From a single commercial premises to an extensive residential property portfolio, our experienced team can provide a reliable, coordinated routine testing programme.
Request Your Free Quote Call 01895 590212Monday to Friday, 9:00 am – 5:00 pm
Complete Fire Safety – One Trusted Partner