Understanding your ongoing fire safety testing responsibilities and keeping your building protected.

Practical guidance on fire alarm testing, emergency lighting, automatic opening vents and routine fire safety management for businesses, landlords and property managers.

Request Your Free Quote Explore Our Testing Services
← Back to the Fire Safety Knowledge Hub

Understanding Your Testing Responsibilities

Different fire safety systems require different testing and maintenance arrangements.

Weekly

Fire Alarm Testing

Routine functional testing of your fire alarm system to help identify operational faults and maintain effective fire safety arrangements.

Monthly

Emergency Lighting Testing

Routine functional checks to confirm emergency lighting operates when its normal electrical supply fails.

Scheduled

Smoke Ventilation & AOVs

Routine operational checks in accordance with the system design, manufacturer guidance and applicable maintenance requirements.

Typical testing arrangements are shown above. Individual requirements depend on the premises, system design and applicable guidance.

What Would You Like to Know?

Choose a category to explore your fire safety testing responsibilities.

Category 02

Fire Alarms, Emergency Lighting & AOVs

How often should a commercial fire alarm be tested?

Fire alarm systems in non-domestic premises should normally be tested weekly in accordance with the recommendations of BS 5839-1.

Testing should normally be undertaken at approximately the same time each week, with suitable arrangements for occupants and any alarm receiving centre.

A different manual call point should normally be used each week where multiple call points are provided.

The results should be recorded and any identified faults reported for appropriate attention.

What does a weekly fire alarm test involve?

A routine weekly test normally involves operating a manual call point and checking that the fire alarm system responds appropriately.

The system should be checked for obvious fault indications and restored to its normal operating condition following the test.

The test should be documented, including the call point tested and any defects identified.

Testing arrangements must account for monitored systems, connected equipment and the building's cause-and-effect arrangements.

Does weekly fire alarm testing replace six-monthly servicing?

No. Weekly fire alarm testing is a routine user check.

Professional inspection and servicing under BS 5839-1 involves more detailed technical checks, with intervals normally not exceeding six months.

Both activities form part of a suitable fire alarm maintenance and management programme.

How often should emergency lighting be tested?

Emergency escape lighting should normally undergo a monthly functional test and an annual full-rated-duration test.

Routine visual monitoring of relevant system indicators may also be required, depending on the system design.

Testing arrangements should follow applicable emergency lighting standards, including BS EN 50172, and manufacturer guidance.

Automatic testing systems may provide an alternative method of undertaking and recording certain tests.

What is a monthly emergency lighting test?

A monthly functional test checks that emergency luminaires operate when their normal electrical supply is interrupted.

This is sometimes referred to as a flick test.

The test should be long enough to confirm operation without unnecessarily discharging the batteries.

Any failed luminaires or other defects should be recorded and reported for appropriate remedial action.

What is an annual emergency lighting duration test?

An annual duration test checks whether emergency lighting continues to operate for its specified rated emergency duration.

Many commercial systems are designed for three hours of emergency operation, although the required duration depends on the building and system design.

Testing must be appropriately planned to account for battery recharge times and the continued safety of building occupants.

A monthly functional test does not demonstrate that a luminaire can achieve its full rated duration.

What is an automatic opening vent or AOV?

An automatic opening vent is a component of a smoke ventilation system designed to open under specified operating conditions.

Depending on the system design, smoke ventilation can help manage smoke within communal corridors, stairwells and other protected areas.

These systems are particularly important in many multi-occupied residential buildings.

How often should AOVs and smoke ventilation systems be tested?

Smoke ventilation systems require appropriate routine checks and specialist maintenance.

Testing frequencies depend on the system design, fire strategy, manufacturer instructions and applicable standards and guidance.

Monthly operational checks may form part of a suitable testing programme, but there is no single universal interval appropriate to every smoke ventilation system.

Additional statutory monthly checking duties apply to relevant smoke control equipment in high-rise residential buildings in England under the Fire Safety (England) Regulations 2022.

Does an AOV operational test replace specialist servicing?

No. Routine operational testing helps identify obvious functional problems but does not replace specialist inspection and maintenance.

Smoke ventilation systems may incorporate detectors, control panels, actuators, power supplies, dampers and other interconnected components.

Specialist maintenance is necessary to assess the system against its intended design and applicable technical requirements.

Category 03

Record Keeping, Outsourcing & Our Services

Do I need to keep records of fire safety testing?

Maintaining suitable testing and maintenance records is an important part of demonstrating effective fire safety management.

Records should normally include:

  • The date of the test.
  • The system or equipment tested.
  • The person undertaking the test.
  • The results of the test.
  • Any faults or defects identified.
  • Details of reporting and follow-up action.

Records should be readily available for management review and inspection by relevant enforcing authorities where required.

What should happen when a fault is identified?

Identified faults should be recorded and reported promptly to the Responsible Person or designated property management contact.

Appropriate remedial action should be arranged through a competent service provider.

Where a fault compromises fire safety arrangements, the Responsible Person should assess the risk and implement suitable interim measures where necessary.

Can I outsource my weekly and monthly fire safety testing?

Yes. Outsourcing routine testing allows businesses and property managers to establish a consistent, scheduled testing programme.

Virtus Fire provides routine compliancy testing services across London and the Home Counties.

Our services are particularly suited to organisations that manage multiple properties, have limited on-site staffing or require reliable testing arrangements throughout the year.

What are the benefits of outsourcing routine testing?
  • Consistent scheduled attendance.
  • Reduced reliance on internal staff.
  • Documented testing records.
  • Prompt reporting of identified faults.
  • Improved oversight across multiple properties.
  • Reduced administrative workload.
  • Predictable ongoing service costs.

Outsourcing supports the Responsible Person in managing their obligations but does not transfer their statutory responsibilities.

Can Virtus Fire manage multiple properties?

Yes. We work with property managers, managing agents, landlords and businesses to deliver coordinated testing programmes across individual buildings and extensive property portfolios.

Our scheduled services help clients maintain consistent testing arrangements without having to coordinate separate internal resources at every location.

How much does compliancy testing cost?

Costs depend on the location, number of properties, systems installed, testing requirements and frequency of attendance.

We provide tailored quotations for individual premises and multi-site property portfolios.

Routine testing can also be incorporated into a bespoke monthly Virtus Fire Compliance Care Plan.

Request Your Free, No-Obligation Quote

Further Fire Safety Guidance

For additional information about fire safety responsibilities and maintenance requirements, consult the following official guidance.

GOV.UK – Workplace Fire Safety →

Regulatory Reform (Fire Safety) Order 2005 – Article 17 →

Fire Safety (England) Regulations 2022 →

This page provides general guidance, principally relating to England. Individual testing and maintenance requirements depend on the premises, system design, applicable standards, manufacturer instructions and fire risk assessment.

125+ Years of combined operational London Fire Brigade experience
IFSM Members of the Institute of Fire Safety Managers
Independent Professional local fire safety support
The Virtus Fire Approach

Reliable Testing. Clear Reporting. Peace of Mind.

Let us take care of your routine fire safety testing programme, so you can concentrate on managing your business or property portfolio.

Scheduled Attendance

Regular testing visits arranged around your building's requirements and agreed service schedule.

Documented Results

Clear records of completed tests to support your ongoing fire safety management arrangements.

Proactive Fault Reporting

Identified defects reported to the appropriate contact, helping you arrange timely remedial action.

The Virtus Fire Compliance Care Plan

Total Compliance. One Cost.

Managing your fire safety responsibilities shouldn't mean juggling multiple contractors, testing schedules and unexpected invoices.

Our bespoke Compliance Care Plans bring your agreed fire safety services together into one coordinated package.

Routine Testing

Weekly fire alarm testing, monthly emergency lighting checks and agreed smoke ventilation testing arrangements.

Wider Fire Safety

Fire risk assessments, fire door inspections, extinguisher servicing and other agreed fire safety services.

Predictable Costs

A tailored service package with manageable monthly payments, designed around your premises and agreed requirements.

Protect What Matters

Let Us Take Care of Your Compliancy Testing

From a single commercial premises to an extensive residential property portfolio, our experienced team can provide a reliable, coordinated routine testing programme.

Request Your Free Quote Call 01895 590212

Monday to Friday, 9:00 am – 5:00 pm

Complete Fire Safety – One Trusted Partner

Working With the Best Clients & Partners

Chat with us